ADFORS Logo
Wall covering by Adfors

See below how Wall Covering by Adfors can contribute to WELL criteria: Reverberation time 

Read more

You have a question? You are looking for a documentation? You need more information?

Don't hesitate to contact our team, we will be pleased to help you.

Contact us!

Aim

To help maintain comfortable sound levels by limiting reverberation times.

Detailed requirement

Part 1: Reverberation Time

The following spaces have maximum reverberation time (RT60) as described:

  • Conference rooms: 0.6 seconds.
  • Open workspaces: 0.5 seconds.

Part 2: Reverberation Time for Learning Spaces

Reverberation time measurements for learning spaces meet the following criteria:

  • Spaces less than or equal to 3,000 m³ [10,000 ft³]: less than 0.6 seconds.
  • Spaces greater than 3,000 m³ [10,000 ft³] and equal to or less than 6,000 m³ [20,000 ft³]: less than 0.7 seconds.

See detailed requirement for Reverberation time

Our contribution

In the context of green architecture, products from the Acoustiver sub-range (Novelio® Renovation) are designed to improve thermal and acoustic comfort while helping in heavy renovation jobs.

More specifically, this range helps to reduce echo phenomena and absorbs up to 40% of noise pollution according to the ISO 11654 norm.

Based on the ISO 354 norm, the acoustic absorption coefficient αw is 0.25.

Acoustic Absorption curve of painted Acoustiver